Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:
1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes.
2) If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibil-
WARNING: 240V DISCONNECT POWER TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS.
Caution: Ensure that the wires do not
touch any hot surfaces and are away
from sharp edges.
M
911-040
240V PLUG
26
This unit is polarity sensitive and will
not operate if polarity is incorrect.

STANDARD WIRING

DIGITAL IGNITION BOARD
SIT 0.579.400
SPARK
12
11
FLAME
White
Receiver
Active SW RED
F
Active BLACK
F
BLUE
BROWN
GAS CONTROL
GROUND

FINAL CHECK

CAUTION
ity of the manufacturer.

WIRING

10
9
8
7
6
5
4
3
2
1
BLUE
BROWN
14 13
BLUE
10 WAY CONNECTOR
BROWN
PURPLE
BLK
RED
RED
WHITE
WHITE
BLUE
BLUE
M
YELLOW
YELLOW
F
BLACK
GREY
PURPLE
PURPLE
ORANGE
ORANGE
BROWN
BROWN
ORANGE
BROWN
BLACK
WHITE
PURPLE
BLUE
BLUE
BLUE
YELLOW/GREEN
RED
RED
BROWN
BLUE
BLUE
BLUE
YELLOW/GREEN
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
RECTIFIER
960.452
PRESSURE SWITCH
N.C.#1
N.O.#2
GREY
COMMON
OVER T EMPERATURE
SWITCH 105°C
911-061
911-060
911-061
TB201-TB-B
TC201-TB-B
TB201-TB-B
SPDT
SPDT
SPDT
ON-OFF-ON
ON-None-ON
ON-None-ON
Fan High
Valve
On
Low
Unit
OFF
Valve
Remote
High
Fan Low
ROOM FAN
COMBUSTION FAN