OPTIONAL MODULAR FIREPLACE SOLUTION INSTALLATION
Follow these instructions to the install the Optional Modular Fireplace Solution
See Installation Manual for overall dimensions and clearances.
Required components
IP28 unit
Modular Fireplace Solution (comes with faceplate
Venting Kit
Before you begin:
Ensure the Modular Fireplace Solution (MFS) is positioned so the gas and electrical connections can enter from the bottom or the back.
1) Follow the installation instructions for the venting and termination as referenced in the installation manual. Please note: WHEN IP 28 IS INSTALLED
WITHIN THE MFS THE UNIT IS RAISED. ENSURE YOUR HOLE TO CENTER IS MARKED AND CUT ACCORDINGLY.
2) Once the hole is prepared to install the venting, place the MFS center of the hole and fl ush against the wall and position the gas line and electrical
accordingly within the MFS. Secure the MFS to the wall using the screws provided. See screw locations in diagram below.
3) Ensure venting is secured to unit and slide unit carefully into the MFS. NOTE: SLIDE UNIT IN PARTIALLY TO ALLOW ACCESS TO CONNECT
GAS AND ELECTRICAL. Once gas and electrical are connected, slide unit in completely.
Regency IP28 Gas Inbuilt Fireplace
Note: Front panel shown as transparent to show screw locations.