Air Conditioning Diagnosis With Gauges For Systems; Evaporator Temperature/Pressure A/C Chart - Mazda 1983 RX7 Service Manual

Table of Contents

Advertisement

Fig. 2:

Evaporator Temperature/Pressure A/C Chart

AIR CONDITIONING DIAGNOSIS WITH GAUGES FOR SYSTEMS WITH
INSUFFICIENT OR NO COOLING TABLE
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
Low Side
High Side
Gauge
Gauge
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
NORMAL
A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES
Article Text (p. 4)
For www.iluvmyrx7.com
Copyright © 1998 Mitchell Repair Information Company, LLC
Sunday, August 26, 2001 04:42PM
Other Symptoms (1)
No or few bubbles in sight
glass. High side gauge may
go high. Low side gauge
does not fluctuate with
compressor on/off cycle.
Cools okay in morning but
not during hot part of day.
Bubbles in sight glass.
Discharge air warm when low
side gauge drops into vacuum.
Thermostatic switch system
only - compressor cycles off
1983 Mazda RX7
Diagnosis
Some Air and
Moisture in
System
Excessive
Moisture in
System
Defective
Thermostatic

Hide quick links: