Network Interface Specifications

* For detailed information about the network interface, take a look at the "Roland-PrintServer User Manual."
Control Area
1. Button
2. Green, ready mode LED
3. Yellow LED receive data and error indicator
4. RJ-45 connector for 100Base-TX and 10Base-T
5. Green, link LED
RJ-45 (Ethernet) connector
Pin
Assignment
1
RX+ (Receive)
2
RX- (Receive)
3
TX+ (Transmit)
4
-
5
-
6
TX- (Transmit)
7
-
8
-
10Base-T Ethernet network cable specifications
Data
Max. cable lenght
Cable type
Impedance
Connector type
100Base-TX Ethernet network cable specifications
Data
Max. cable lenght
Cable type
Impedance
Connector type
94
Input or output
IN
IN
OUT
-
-
OUT
-
-
Values
100 m
S/UTP Type "category 5"
100 Ohm
RJ-45
Values
100 m
S/UTP Type "category 5"
100 Ohm
RJ-45