Replacing A Hot-Pluggable Disk Drive; Removing And Replacing A Hot-Pluggable Pci/Pci-X Card - HP Integrity rx6600 User's & Service Manual

Hide thumbs Also See for Integrity rx6600:
Table of Contents

Advertisement

Replacing a Hot-Pluggable Disk Drive

To install a hot-pluggable disk drive, follow these steps:
Step 1. Use Figure 4-10 to determine the next available disk drive installation slot.
NOTE
Step 2. Remove the disk drive filler if required. See "Removing and Replacing a Hot-Swappable Disk Drive
Filler" on page 68.
NOTE
Step 3. Insert the hot-pluggable disk drive into the slot guides, and slide the drive into the slot until it
seats into the socket on the disk backplane.
Step 4. Close the extraction handle by pushing it inward until it clicks into place.
Step 5. Observe the following disk drive LEDs to ensure the drive is functional. For more information, see
"Hot-Pluggable Disk Drive LEDs" on page 37.
Drive status LED
Drive activity LED

Removing and Replacing a Hot-Pluggable PCI/PCI-X Card

PCI/PCI-X cards are located on the I/O board assembly. Two of these cards are dedicated to core I/O functions
and require that the server be powered off for card replacement. Core I/O cards have designated slots on the
I/O board assembly. The remaining eight PCI/PCI-X cards are hot-pluggable. Software intervention is
required prior to removing a PCI/PCI-X card. This section describes the following hot-plug operations and
PCI/PCI-X card replacement procedures:
PCI/PCI-X Configurations
Describes PCI/PCI-X capabilities and relates card functions and capabilities to specific slots.
Online Addition (OLA)
Describes the installation of new PCI/PCI-X expansion cards in previously empty slots without powering
down the server.
Online Replacement (OLR)
Describes the replacement of a PCI/PCI-X card without powering down the server. This action requires
suspending the associated driver. The existing driver for the old card must be compatible with the new
card.
Chapter 4
Drives are loaded in order, starting with number 1, working from left to right and top
to bottom.
Save the disk drive filler for future use. For cooling purposes, always place disk drive
fillers in slots that do not contain a disk drive.
Removing and Replacing a Hot-Pluggable PCI/PCI-X Card
Removal and Replacement
73