Compaq Deskpro EN Series Maintenance & Service Manual page 142

Small form factor and net pc models
Hide thumbs Also See for Deskpro EN Series:
Table of Contents

Advertisement

912-Computer Cover
None
Has Been Removed
Since Last System
Startup
1151-System Board
2S
Comm Port 1 Address
Assignment Conflict
1152-System Board
2S
Comm Port 2 Address
Assignment Conflict
1720-SMART Hard
None
Drive detects
imminent failure
1721-SMART SCSI
None
Hard Drive detects
imminent failure
1771-Primary
2S
Disk Port Address
Assignment Conflict
2S
1772-Secondary
Disk Port Address
Assignment Conflict
1780-Disk 0 Failure
None
1781-Disk 1 Failure
None
1782-Disk Controller
None
Failure
1790-Disk 0 Failure
None
1791-Disk 1 Failure
None
L=Long, S=Short
Both external and
internal serial ports
are assigned to COM1.
Both external and
internal serial ports
are assigned to COM2.
Hard drive is about to
fail.
Hard drive is about to
fail.
Internal and external
hard drive controllers
are both assigned to
the primary address.
Internal and external
hard drive controllers
are both assigned to
the secondary address.
Hard drive/format error.
Hard drive/format error.
Hard drive circuitry
error.
Hard drive error or
wrong drive type.
Hard drive error or
wrong drive type.
Compaq Deskpro EN Series, Small Form Factor and Net PC Models
No action required.
Run Computer Setup or Windows NT
or Windows 95 utilities.
Run Computer Setup or Windows NT
or Windows 95 utilities.
Back up contents and replace hard drive.
Back up contents and replace hard drive.
Run Computer Setup or Windows NT
or Windows 95 utilities.
Run Computer Setup or Windows NT
or Windows 95 utilities.
Run the Configuration and Diagnostics
utilities.
Run the Configuration and Diagnostics
utilities.
Run the Configuration and Diagnostics
utilities.
Run the Configuration and Diagnostics
utilities.
Run the Configuration and Diagnostics
utilities.