• When 6" diameter decorative pipe is installed to
cover the venting any Listed Flexible Gas liner must
be connected directly to the stove's draft hood.
• Use of single wall connector pipe as a vent is prohib-
ited for use with the GF400 Sebago B-Vent stove.
• A firestop is required at every floor.
• Any venting that is exposed above the first floor,
regardless of attic space or living space, must be
enclosed. Always maintain the required clearance
from all sides of the vertical vent system according
to manufacture.
• Installation of any components not manufactured or
approved by Jøtul or failure to meet all clearance re-
quirements will void all warranties and could result
in property damage, bodily injury, or serious fire.
• Never modify any venting component, or use any
damaged venting product.
• THE GAS APPLIANCE AND VENT SYSTEM MUST BE
VENTED DIRECTLY TO THE OUTSIDE OF THE BUILD-
ING, AND NEVER ATTACHED TO A CHIMNEY SERVING
A SOLID FUEL OR GAS BURNING APPLIANCES.
• BE SURE TO MAINTAIN THE PROPER CLEARANCES TO
COMBUSTIBLES AS DEFINED IN THIS MANUAL AND
IN THE INSTRUCTIONS PROVIDED WITH EACH VENT-
ING COMPONENT.
• When installing at an altitude above 2000' the mini-
mum vertical rise becomes 12' from the draft hood.
A chimney system located outside the building
envelope may be subject to downdrafting
and/or flow reversal. Atmospherically-vented ap-
pliances, such as B-Vents, may not be compatible
with these chimney systems.
All atmospherically-vented appliances (B-Vents)
are affected by atmospheric conditions and house
pressurization. For example, a B-Vent appliance
vented to an outside chimney system in a base-
ment will likely be subject to negative pressure.
This type of installation is not recommended.
NOTE:
Venting through a Masonry or
Prefabricated Manufactured
Chimney
Top sealing
achor plate
Type B vent or
Listed Flexible Gas
Liner.
Use of Type B
vent liner within
outside chimneys
is recommended to
help keep the gases
warm and stabilize
draft.
Max. Height 35 ft.
Min. Height 7 ft.
Always
maintain
the proper
clearance to
mantel and
Maximum
offset is 4 ft.
Recommended
damper sealing plate
to seal flue chamber
to prevent heat loss
WARNING: FAILURE TO POSITION THE PARTS IN ACCOR-
DANCE WITH THIS DIAGRAM OR FAILURE TO USE ONLY
PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE
MAY RESULT IN PROPERTY DAMAGE OR PERSONAL
INJURY.
Figure 6. Venting through a masonry chimney.
138301_Rev_G 10.4.11
Listed termi-
Storm collar
nation cap
required
required
trim
9