Parameter
6.16
Misoperation prevention and parameter setting
restriction
Purpose
Limit reset function
Make alarm stop when PU is
disconnected
Stop from PU
Prevention of parameter rewrite
Prevention of reverse rotation of the
motor
Display necessary parameters
Parameter restriction using
password
6.16.1
Reset selection/disconnected PU detection/PU stop selection (Pr. 75)
You can select the reset input acceptance, disconnected PU (FR-DU07/FR-PU04/FR-PU07)
connector detection function and PU stop function.
Pr.
Name
No.
Reset selection/
disconnected PU
75
detection/
PU stop selection
The above parameter can be set when Pr. 160 = 0.
The Pr. 75 value can be set any time. Also, if parameter (all) clear is executed, this setting will
not return to the initial value.
The above parameter allows its setting to be changed during operation in any operation mode
even if "0" (initial value) or "1" is set in Pr. 77 "Parameter write selection".
FR-F700 EC
Parameters that must be set
Reset selection/
disconnected PU detection/
PU stop selection
Parameter write selection
Reversierverbot
Reverse rotation prevention selection
Password function
Initial
Setting
Value
Range
01160
0–3/
or
14–17
less
14
0–3/
01800
14–17/
or
100–103/
more
114–117
Misoperation prevention and parameter setting restriction
Description
For the initial value, reset always
enabled, without disconnected PU
detection, and with PU stop func-
tion are set.
Refer to
Section
Pr. 75
6.16.1
Pr. 77
6.16.2
Pr. 78
6.16.3
Pr. 160,
6.16.4
Pr. 172–Pr. 174
Pr. 296, Pr. 297
6.16.5
Parameters referred to
250
Stop selection
Refer to
Section
6 - 213