Frequency Setting By External Terminals; (Pr. 4 To Pr. 6, Pr. 24 To Pr. 27, Pr. 232 To Pr. 239); Multi-Speed Setting Operation - Mitsubishi Electric FR-F740 EC Instruction Manual

Fr-f700 series
Table of Contents

Advertisement

Parameter
6.5

Frequency setting by external terminals

Purpose
Make frequency setting by combina-
tion of terminals
Perform jog operation
Added compensation for multi-
speed setting and remote setting
Infinitely variable speed setting by
terminals
6.5.1

Multi-speed setting operation

(Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)

Can be used to change the preset speed in the parameter with the contact signals.
Any speed can be selected by merely turning on-off the contact signals (RH, RM, RL, REX
signals).
Pr.
Name
No.
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
Multi-speed setting
24
(speed 4)
Multi-speed setting
25
(speed 5)
Multi-speed setting
26
(speed 6)
Multi-speed setting
27
(speed 7)
Multi-speed setting
232
(speed 8)
Multi-speed setting
233
(speed 9)
Multi-speed setting
234
(speed 10)
Multi-speed setting
235
(speed 11)
Multi-speed setting
236
(speed 12)
Multi-speed setting
237
(speed 13)
Multi-speed setting
238
(speed 14)
Multi-speed setting
239
(speed 15)
The above parameter can be set when Pr. 160 = 0.
NOTE
The above parameters allow its setting to be changed during operation in any operation
mode even if "0" (initial value) is set in Pr. 77 "Parameter write selection".
FR-F700 EC
Parameters that must be set
Multi-speed operation
Jog operation
Multi-speed input compensation selection
Remote setting function
Initial
Setting Range Description
Value
Set the frequency when RH
50Hz
0–400Hz
turns on.
Set the frequency when RM
30Hz
0–400Hz
turns on.
Set the frequency when RL turns
10Hz
0–400Hz
on.
9999
0–400Hz/9999
9999
0–400Hz/9999
9999
0–400Hz/9999
9999
0–400Hz/9999
9999
0–400Hz/9999
Frequency from speed 4 to
9999
0–400Hz/9999
speed 15 can be set according
to the combination of the RH,
RM, RL and REX signals.
9999
0–400Hz/9999
9999: not selected
9999
0–400Hz/9999
9999
0–400Hz/9999
9999
0–400Hz/9999
9999
0–400Hz/9999
9999
0–400Hz/9999
Frequency setting by external terminals
Pr. 4–Pr. 6,
Pr. 24–Pr. 27
Pr. 232–Pr. 239
Pr. 15, Pr. 16
Pr. 28
Pr. 59
Parameters referred to
1
Maximum
frequency
2
Minimum
frequency
15
JOG frequency
28
Multi-speed input
compensation
selection
59
Remote function
selection
178–189
Input terminal
function selection
Refer to
Section
6.5.1
6.5.2
6.5.3
6.5.4
Refer to
Section
6.3.1
6.3.1
6.5.2
6.5.3
6.5.4
6.9.1