Parameter overview
Parameter
Func-
Name
tion
Operation selection at
502
communication error
Operation frequency
during communication
779
error
503
Maintenance timer
Maintenance timer
504
alarm output set time
505
Refer to Pr. 37
506
Refer to Pr. 414 and Pr. 415
515
522
Output stop frequency
Modbus-RTU
539
communication check
time interval
549
Refer to Pr. 117 to Pr. 124
550
Refer to Pr. 338 and Pr. 339
551
553
Refer to Pr. 127 to Pr. 134
554
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
561
Refer to Pr. 9
Tab. 6-1:
Parameter overview (28)
These parameters are communication parameters that are not cleared when parameter
clear (all clear) is executed from RS485 communication. (Refer to section 6.18.3 for RS485
communication).
6 - 28
Incre-
Initial
Setting
ments
Value
Range
0
1
1
0
2
3
0–400Hz
0.01Hz
9999
9999
1
0
0 (1–9998)
0–9998
1
9999
9999
0–400Hz
0.01Hz
9999
9999
0
0.1s
9999
0.1–999.8s
9999
0.1s
1s
0.1–1.0s
0.1s
0s
0.0–20.0s
Rated
0.01/
0–500/
inverter
0.1A *
0–3600A *
current
Description
You can select
Coasts to stop
the inverter
Decelerates to
operation if a
stop
communica-
tion error
Continues run-
occurs.
ning at Pr. 779
Motor runs at the specified fre-
quency at a communication error.
Motor runs at the frequency used
before the communication error.
Display the cumulative energizing
time of the inverter in 100h incre-
ments. Reading only
Writing the setting of "0" clears the
cumulative energizing time.
Set the time taken until when the
maintenance timer alarm output
signal (Y95) is output.
No function
Set the frequency to start coasting
to a stop (output shutoff).
No function
Modbus-RTU communication can
be made, but the inverter will
come to trip in the NET operation
mode.
Set the interval of communication
check time. (Same specifications
as Pr. 122)
No communication check (signal
loss detection)
Set the time taken to average the
current during start bit output
(1s).
Set the time for not obtaining
(mask) transient state data.
Set the reference (100%) for out-
putting the signal of the current
average value
* Setting increments and setting
range differ according to the
inverter capacity:
(01160 or less/01800 or more)
Parameter
All
Para-
Para-
para-
meter
meter
meter
copy
clear
Refer
clear
to
page
✔: enabled
—: disabled
6-289
6-394
6-107
6-289
6-395