Stop Selection (Pr. 250) - Mitsubishi Electric FR-F740 EC Instruction Manual

Fr-f700 series
Table of Contents

Advertisement

Parameter
6.8.3

Stop selection (Pr. 250)

Used to select the stopping method (deceleration to a stop or coasting) when the start signal
turns off. Used to stop the motor with a mechanical brake, etc. together with switching off of the
start signal. You can also select the operations of the start signals (STF/STR). (Refer to section
6.9.4 for start signal selection.)
Pr.
Initial
Name
No.
Value
250
Stop selection
9999
The above parameter can be set when Pr. 160 = 0.
Set Pr. 250 to "9999" (initial value) or "8888". The motor decelerates to a stop when the start sig-
nal (STF/STR) turns off.
Fig. 6-53:
Use Pr. 250 to set the time from when the start signal turns off until the output is shut off. When
any of "1000" to "1100" is set, the output is shut off after (Pr. 250 − 1000)s.
The output is shut off when the time set in Pr. 250 has elapsed after the start signal had turned
off. The motor coasts to a stop.
Fig. 6-54:
FR-F700 EC
Description
Setting
Start Signal
Range
(STF/STR)
STF: Forward
rotation start
0–100s
STR: Reverse rotation
start
STF: Start signal
1000s–
STR: Forward/reverse
1100s
signal
STF: Forward
rotation start
9999
STR: Reverse
rotation start
STF: Start signal
8888
STR: Forward/reverse
signal
Output
frequency [Hz]
Start signal
RUN signal
Stop operation when parameter 250 = 9999
Output
frequency [Hz]
Start signal
RUN signal
Stop operation when parameter 250
Stop Operation
The motor is coasted to a
stop when the preset time
elapses after the start signal
is turned off.
The motor is coasted to a
stop (Pr. 250 − 1000)s after
the start signal is turned off.
When the start signal is
turned off, the motor decel-
erates to stop.
Deceleration starts when start signal turns off
Deceleration time (Time set to Pr. 8, etc.)
ON
OFF
ON
OFF
Output is shut off when set time elapses after start
signal turned off
Pr. 250
Motor coasts to stop
ON
OFF
ON
OFF
8888 or 9999
Motor brake and stop operation
Parameters referred to
7
Acceleration time
8
Deceleration time
13
Starting frequency
DC brake
Time
Time
Refer to
Section
6.6.1
6.6.1
6.6.2
I001143E
I001144E
6 - 105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-f746 ec

Table of Contents