How To Check The Serial Number - Canon Color imageRUNNER LBP5280 Service Manual

Color imagerunner lbp5280
Table of Contents

Advertisement

2
Technical Reference > MEAP > Preparation for Using SMS > How to Check the Serial Number
9) A message will appear to indicate that import has been completed successfully. Click the [
OK ] button.
● Network Port Settings
The default port of the HTTP server used for MEAP and MEAP applications to provide the
servlet function is 8000, and the HTTPS server's default port is 8443. In the case that these
ports have already used by the customer who is to introduce this application, the MEAP
application cannot use the HTTP (or HTTPS) server(s).
By changing the following ports to use, however, the MEAP application can be used as well
as the existing system.
The procedure for setting the HTTP/HTTPS server port is shown below.
1) Start service mode. From the [ Setup ] menu, select [ SERVICE MODE ] > [ FUNCTION
GR. ] > [ MEAP ].
Setup
PS
SERVICE MODE
MEAP Settings
ADJUST GR.
Check
Counter
OPTION GR.
SERVICE MODE
FUNCTION GR.
LOG GR.
2) To set up the HTTP server port, select [ MEAP-PN ]. To set up the HTTPS server port, select [
MEAP-SSL ]. When the port number setting screen appears, specify a port number. Use
the Up and Down keys to specify the setting.
MEAP
MEAP-PN
MEAP-SSL
CDS-MEAP
CDS-FIRM
2
Technical Reference > MEAP > Preparation for Using SMS > How to Check the Serial Number
F-2-74
FUNCTION GR.
COLOR MODE SLCT
MEAP
DDNSINTY
IPMTU
F-2-75
MEAP-SSL
8443
(0-65535)
F-2-76
Note:
A port number can be any integer from 0 to 65535. To avoid port numbers that are
frequently used, do not use any integer from 0 to 1023.
Server
Setting value
HTTP Server
1024 to 65535
HTTPS Server
1024 to 65535
Note:
If PS Print Server Unit is connected, do not specify port 8080.
If port 8080 is specified, the RUI of the device where the MEAP authentication
application is running cannot be displayed. (Port 8080 is reserved to allow the PS Print
Server Unit to redirect to the iR device.)
3) Restart the device if the port number is set.

■ How to Check the Serial Number

When performing MEAP device support, the serial number of the device is necessary in some
cases.
Examples of where the serial number is necessary
• When initializing SMS login password (obtaining a switch license)
• When obtaining a MEAP application license from LMS
• When obtaining a transfer license of MEAP application
• When obtaining a special license for reinstalling MEAP application
If a problem occurs in the MEAP device and you want to contact the support department of
the sales company, you need to provide the serial number. Perform the following procedure to
get the serial number.
2-41
Default value / Value after RAM clear
8000
8443
T-2-8
2-41

Advertisement

Table of Contents
loading

Table of Contents