Displaying Temperatures for Modules

Xb3
N7K-C7010-FAB-1
Xb4
N7K-C7010-FAB-1
Xb5
N7K-C7010-FAB-1
fan1
N7K-C7010-FAN-S
fan2
N7K-C7010-FAN-S
fan3
N7K-C7010-FAN-F
fan4
N7K-C7010-FAN-F
N/A - Per module power not available
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured)
Power Supply redundancy mode (operational)
Total Power Capacity (based on configured mode)
Total Power of all Inputs (cumulative)
Total Power Output (actual draw)
Total Power Allocated (budget)
Total Power Available for additional modules
switch#
Displaying Temperatures for Modules
Each supervisior, I/O, and fabric module has temperature sensors with two thresholds:
• Minor temperature threshold—When a minor threshold is exceeded, a minor alarm occurs and the
• Major temperature threshold—When a major threshold is exceeded, a major alarm occurs and the
Cisco Nexus 7706 Hardware Installation Guide
54
N/A
N/A
N/A
following actions occur for all four sensors:
◦ Displays system messages
◦ Sends Call Home alerts (if configured)
◦ Sends SNMP notifications (if configured)
following actions occur:
◦ For sensors 1, 3, and 4 (outlet and onboard sensors), the following actions occur:
◦ Displays system messages.
◦ Sends Call Home alerts (if configured).
◦ Sends SNMP notifications (if configured).
◦ For sensor 2 (intake sensor), the following actions occur:
◦ If the threshold is exceeded in a switching module, only that module is shut down.
◦ If the threshold is exceeded in an active supervisor module with HA-standby or standby
present, only that supervisor module is shut down and the standby supervisor module takes
over.
◦ If you do not have a standby supervisor module in your switch, you have up to 2 minutes to
decrease the temperature. During this interval, the software monitors the temperature every
5 seconds and continuously sends system messages as configured.
60 W
Powered-Up
60 W
Powered-Up
60 W
Powered-Up
88 W
720 W
Powered-Up
88 W
720 W
Powered-Up
9 W
120 W
Powered-Up
9 W
120 W
Powered-Up
Redundant
Redundant
18000 W
Managing the Switch
9000 W
2259 W
4750 W
4250 W
OL-31330-01