Installing the Chassis on a Four-Post Rack or Cabinet

d) Press the ejector button on the front of the module, to release the levers from the front of the module.
e) Rotate the levers away from the front of the module and hold them while sliding the module all the way into the slot.
f) Simultaneously rotate both levers to the front of the module. They click when locked to the front of the module.
Step 10
If you removed any fan trays before moving the chassis, reinstall each one in the chassis as follows:
a) Holding each of the two handles on the fan tray with your two hands, align the fan tray to an open fan tray slot.
The two alignment brackets on top of the fan tray should align to two tracks at the top of the
Note
slot.
b) Slide the fan tray into the slot until the front of the fan tray comes in contact with the rear of the chassis.
Note
The two alignment pins on the fan tray (on the top and one on the bottom) should go into holes in the chassis
and the four captive screws on the fan tray should align to screw holes in the chassis.
c) Screw in the four captive screws to the chassis and tighten each screw to 8 in-lb (0.9 N·m).
Step 11
If you removed any power supplies before moving the chassis, reinstall each one as follows:
a) Determine which power supply slots to fill and ensure that each of those slots is open.
If you are using the combined or power supply redundancy mode, you can use any slot for the power supply that you
are installing. If you are using the input-source or full redundancy mode, you must group the power supplies that are
to be connected to the same grid on either the left or right power supply slots in the chassis (that is, place the power
supplies for grid A in slots 1 or 2 or both slots and place the power supplies for grid B in slots 3 or 4 or both slots).
b) Place one hand on the front of the power supply and place your other hand under it to support its weight.
c) Align the power supply to an open power supply slot.
The alignment bracket on top of the power supply should align to a track at the top of the slot and a bar at
Note
the bottom of the power supply should be guided by a track at the bottom of the slot.
d) Slide the power supply all the way into the slot until its release handle clicks and the module stops.

Installing the Chassis on a Four-Post Rack or Cabinet

Before You Begin
• Verify that the chassis shipment is complete and undamaged.
• Verify that a rack or cabinet is installed and secured to the subfloor.
• Verify that the bottom-support rails have been attached to the lowest possible RU in the rack or cabinet
• If there are other devices in the rack, verify that the devices that are heavier than this chassis are installed
Cisco Nexus 7706 Hardware Installation Guide
24
Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be
Warning
bolted to the floor before you slide the unit out for servicing. Failure to stabilize the
rack can cause the rack to tip over.
Statement 1048
and there is 9 RU (15.75 inches [40.0 cm]) of space above the rails to install the chassis.
below where you are going to install the chassis and lighter devices are installed above where you are
going to install the chassis.
Installing the Switch Chassis