Typical Pit Counter Value Load Subroutine; Typical Pit Counter Read Subroutine - Intel iSBC 86/14 Hardware Reference Manual

Intel single board computer hardware reference manual
Table of Contents

Advertisement

PROGRAMMING INFORMATION
Table 3-6.
Typical PIT Counter Value Load Subroutine
LOADO LOADS COUNTER 0 FROM CX, CH IS MSB, CL IS LSB.
USES-D,E:
DESTROYS-AL.
CX MUST BE LOADED PRIOR TO CALLING THE ROUTINE.
PUBLIC
LOADO
LOADO:
MOV
AL,CL
:GET LSB
OUT
ODOH,AL
MOV
AL,CH
:GET MSB
OUT
ODOH,AL
RET
END
Table 3-7.
Typical PIT Counter Read Subroutine
READl READS COUNTER
1
ON-THE-FLY INTO CX, MSB IN CH, LSB IN CL:
DESTROYS-AL,CX.
PUBLIC
READl:
MOV
OUT
IN
MOV
IN
MOV
RET
END
READl
AL,4OH
OD6H,AL
AL,OD2H
CL,AL
AL,OD2H
CH,AL
;MODE WORD FOR LATCHING COUNTER 1
VALUE
;LSB OF COUNTER
;MSB OF COUNTER
3-15