EPSON AcuLaser CX11/CX11F
Maintenance
Code
Label
Main Sub
LIN_DIALTONE_DETECT_TIME
300
LIN_RING_DETECT_TIME
300
LIN_ONHOOK_DETECT_TIME
300
LIN_DIALTONE_DETECTION
300
LIN_DIALTONE_FREQ
300
LIN_BUSYTONE_FREQ
300
LIN_BUSYTONE_PATTERN
300
LIN_NCU_TYPE
300
LIN_20PPS_ENABLE
300
LIN_DP_RELAY_DELAY
300
LIN_DIAL_NG_NUMBER
300
LIN_RING_INVALID_TIME
300
APPENDIX
Table 7-18. List of System Parameter (Phone Line)
User
Internal
Access
Address
---
Dial tone detecting time out
027
05F
---
Ring detecting time
030
060
The time from detecting ring until it is judged as dialing
---
Off-hook detection time
031
061
Time limit for attached phone off-hook condition to regard it as a
shut-off signal
---
Enables or disables detection of dial tone
032
062
Select whether detect or not detect dial tone immediately after
detecting off-hook condition when the line type is set to PSTN.
When this is set to "disable", blind dialing is perfomed.
---
Dial tone frequency
033
063
---
Busy tone frequency
034
064
---
Busy tone pattern
035
065
---
NCU type
036
066
---
Enables or disables 20 PPS setting
037
067
When this is set to "disable", 20 PPS setting specified in the dial
type setting (300-001) becomes invalid.
---
Waiting time until the line stabilizes when performing pulse dialing 0 to 2550 ms (1 setp = 10 ms)
038
068
---
Allows or not allows to store emergency phone number into the
039
069
speed-dial memory
Emergency phone number: XXXXX
---
Time for judging ring signal is OFF
040
06A
The time limit for ring signal. The line is shut-off if the time exceeds
the set value.
Description
Fax Unit System
manuals4you.com
manuals4you.com
Setting Value
0 to 255 sec (1 step = 1 sec)
100 to 2550 ms (1 step = 10 ms)
200 to 5100 ms (1 step = 20 ms)
0 = Enable (detect)
1 = Disable (not detect)
0 = 350 to 450Hz
1 = 300 to 500Hz
2 = 450 to 650Hz
0 = 400Hz
1 = 350 to 450Hz
2 = 300 to 500Hz
3 = 450 to 650Hz
~
0 = ON 0.30
0.80S
~
OFF 0.30
0.80S
~
1 = ON 0.20
0.60S
~
OFF 0.30
0.60S
~
2 = ON 0.50
1S
~
OFF 0.50
1S
~
3 = ON 0.12
1.2S
~
OFF 0.12
1.2S
0 = For Japan
0 = Enable
1 = Disable
0 = Allows
1 = Not allows
0 to 2550 ms (1 step = 10 ms)
0 = 125 ms
Revision B
Default
Remarks
20 seconds
---
(20)
---
180ms
(18)
---
1300ms
(65)
Disable
---
(1)
---
400Hz
(0)
---
400Hz
(0)
---
(0)
Not used
(0)
Enable
---
(0)
---
10ms
(1)
Allows
Fixed to 0
(0)
Not used
---
125ms
(0)
642