Fip-C4; Fip-C5 - Epson AcuLaser CX11 Service Manual

Color multi-function page printer
Hide thumbs Also See for AcuLaser CX11:
Table of Contents

Advertisement

EPSON AcuLaser CX11/CX11F

FIP-C4

Panel Message
Service Req C1200
Possible parts that caused the error
PWBA ESS
Troubleshooting
Step
Check
Check of EEPROM
1
Initialize the EEPROM. Refer to
of EEPROM" (p.69)
Does the error occur?
External noise
2
1. Check the surrounding of the printer for
electrical equipment.
2. Disconnect all cables connected to the
printer, except the AC cable, and make
operation check.
Does the error occur?
TROUBLESHOOTING
Service Req C1210
Yes
To Step [2]
End of procedure
"Initialization
Replace the
End of procedure
PWBA ESS
.
(p.437)

FIP-C5

Panel Message
Service Req C2000
Possible parts that caused the error
PWBA ESS
Troubleshooting
Step
No
Check of host PC
1
Restart the host PC.
Does the error occur?
Check of Printer Driver
2
Reinstall the Printer Driver.
Does the error occur?
External noise
3
1. Check the surrounding of the printer for
electrical equipment.
2. Disconnect all cables connected to the
printer, except the AC cable, and make
operation check.
Does the error occur?
Printer
Check
Yes
To Step [2]
To Step [3]
Replace the
PWBA ESS
(p.437)
Revision B
No
End of procedure
End of procedure
End of procedure
.
247

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aculaser cx11f

Table of Contents