Download Print this page

Aprilaire 8825 Installation, Configuration And User Manual page 16

System controller

Advertisement

%#
The System Controller can accommodate up to 16 Model 8870 thermostats connected with one or more
Model 8818 Distribution panels. Each thermostat on the thermostat network must have a unique ID.
Note that Model 8870 thermostats may also be set up as humidistats. Throughout this manual we refer to
both as thermostats.
To automatically scan for thermostats:
Automatic detection is best for new installations, and sets a default name ("Thermostat 1", etc.) for each:
1. On the Climate tab, select Aprilaire Model 8818 under Communication Devices, as shown above.
2. Click the Discover Devices button at the lower right of the screen: click OK if prompted.
3. Wait for the process to complete: you will then see a list of the thermostats in the system component
tree.
4. To change the name of the thermostat:
Click the desired thermostat in the system component tree
Edit the Name box in the properties window and change the name as desired and press Enter.
To manually add thermostats:
This procedure is useful to add just one thermostat to a system that has already been setup.
1. On the Climate tab, select Thermostats in the tree structure.
2. Click the Add New ... button.
3. Type in the desired name for the thermostat.
4. Click OK: the parameters window for the new thermostat appears on the right.
5. Select the newly added thermostat in the Thermostats section of the tree structure.
"