Status LEDs

The MX7 Tecton does not have a Bluetooth managed LED. Bluetooth activity indicators are located in the Desktop
l
taskbar.
System Status LED is located at the top left of the keypad, above the Scan button.
l
The Scan Status LED is located below the keypad.
l
The Alpha Mode LED is located below the F4 key on the 32-key keypad (Numeric-Alpha keypad).
l
LED
Color - Activity
Red - Blinking
Red - Steady
System Status
Green - Blinking
No Color
Green - Steady
Red – Steady
Scan Status
No color
Amber - Steady
Green - Steady
Alpha Mode
(Alph LED)
No color
2-8
Indicates ...
Power fail. Replace the main battery with a fully charged main battery.
Or
Connect the MX7 Tecton to external AC power then replace the main bat-
tery with a fully charged main battery.
Main Battery Low. If the main battery is not replaced with a fully charged
battery before the main battery fails, the MX7 Tecton is turned Off.
Display Off. No user intervention required.
MX7 Tecton is either full on - with the display on (backlights may be
dimmed when the status LED has no color) or in Suspend - with the dis-
play off.
Good scan.
Scan in progress.
Integrated Scanner / Imager ready for use.
Bar code decoder engine is storing changed parameters.
MX7 Tecton 32-key is in Alpha character input mode.
MX7 Tecton 32-key is in Numeric key input mode.