Data Options - Symbology Settings

Start > Settings > Control Panel > Data Collection > Data Options > Symbology Settings button
The Symbology selected in the Symbology drop-down list defines the symbology for which the data is being configured. The
features available on the Symbology panel include the ability to
individually enable or disable a bar code from scanning,
l
set the minimum and maximum size bar code to accept,
l
strip Code ID,
l
strip data from the beginning or end of a bar code,
l
or (based on configurable Barcode Data) add a prefix or suffix to a bar code.
l
The Code ID drop-down box only filters the available symbologies in the Symbology drop down box by the selected Code ID.
This Code ID box does not enable or disable the Code ID as that function is controlled by the Enable Code ID box on the Data
Options tab.
The Symbology drop-down box contains all symbologies supported based on the Code ID selected above. An asterisk appears
in front of symbologies that have already been configured or have been modified from the default value.
Each time a Symbology is changed, the settings are saved as soon as the OK button is tapped. Settings are also saved when
a new Symbology is selected from the Symbology drop-down list.
4-89