Entering Commands In Config Mode; Guidelines: Config Commands; Displaying Current Gateway Settings - Motorola Netopia 7000 Administrator's Handbook

Embedded software version 7.8.2
Hide thumbs Also See for Netopia 7000:
Table of Contents

Advertisement

Administrator's Handbook
K Moving from any subnode to any other subnode — You can move from any subnode to any other
subnode by entering a partial path that starts with a top-level CONFIG command.
K Scrolling backward and forward through recent commands — You can use the Up and Down
arrow keys to scroll backward and forward through recent commands you have entered. When the
command you want appears, press Enter to execute it.

Entering Commands in CONFIG Mode

CONFIG commands consist of keywords and arguments. Keywords in a CONFIG command specify the
action you want to take or the entity on which you want to act. Arguments in a CONFIG command specify
the values appropriate to your site. For example, the CONFIG command
set ip ethernet A ip_address
consists of two keywords (
the command to configure your Gateway, you would replace the argument with a value appropriate to
your site.
For example:
set ip ethernet A 192.31.222.57

Guidelines: CONFIG Commands

The following table provides guidelines for entering and formatting CONFIG commands.
Command
component
Command verbs
Keywords
Argument Text
Numbers
IP addresses
If a command is ambiguous or miskeyed, the CLI prompts you to enter additional information. For exam-
ple, you must specify which virtual circuit you are configuring when you are setting up a Motorola Neto-
pia® Gateway.

Displaying Current Gateway Settings

view
You can use the
Gateway. If you enter the
settings for all enabled functions. If you enter the
settings for that node and its subnodes.
146
,
ip
ethernet A
and
Rules for entering CONFIG commands
CONFIG commands must start with a command verb (set, view, delete).
You can truncate CONFIG verbs to three characters (set, vie, del).
CONFIG verbs are case-insensitive. You can enter "SET," "Set," or "set."
Keywords are case-insensitive. You can enter "Ethernet," "ETHERNET," or "ethernet" as a
keyword without changing its meaning.
Keywords can be abbreviated to the length that they are differentiated from other key-
words.
Text strings can be as many as 64 characters long, unless otherwise specified. In some
cases they may be as long as 255 bytes.
Special characters are represented using backslash notation.
Text strings may be enclosed in double (") or single (') quote marks. If the text string
includes an embedded space, it must be enclosed in quotes.
Special characters are represented using backslash notation.
Enter numbers as integers, or in hexadecimal, where so noted.
Enter IP addresses in dotted decimal notation (0 to 255).
command to display the current CONFIG settings for your Motorola Netopia®
view
command at the top level of the CONFIG hierarchy, the CLI displays the
) and one argument ( ip_address ). When you use
view
command at an intermediate node, you see

Advertisement

Table of Contents
loading

Table of Contents