13) TOF DELTA
Sets the minimum media sensor
change required to signify a label
gap or mark.
Possible Values:
Range: 0 – 50; nominal = *10
(Units = .1 volt)
16) SCALABLE FONT
Sets the number of memory blocks
to allocate for scalable fonts.
Possible Values:
Range: 0 – 128; default = *64
(Units = 4K Bytes)
19) ALIGN LENGTH
Leading edge distance of two successive labels.
Must be entered if 'LABEL ALIGNMENT' is set
to Yes (see Section 4.6).
Possible Values:
0 – 999; default =100*
(Units = .01 inch)
24
14) TOF LOW
Sets the minimum media sensor
reading for paper (gap/notch) or mark
(reflective).
Possible Values:
Range: 0 – 50; nominal = *0
(Units = 0.1 volt)
17) INTERNAL MODULE
Sets the number of memory blocks to
allocate for the internal RAM module.
Possible Values:
Range: 0 – 128; default = *128
(Units = 4K Bytes)
20) OPTION CONTROL
Sets label stopping (and in certain cases the starting) location for
different printer configurations.
Possible Values:
* AUTO (Automatically sets the stop location. Installed options
will be 'auto-sensed' and the appropriate stop position
will automatically be set. Host commands are ignored.)
HOST
(Sets stop position according to options installed. If no
options are installed the printer sets stop location to the
next label's start of print. Host commands will
override.)
15) LABEL WIDTH
Sets the label width.
Possible Values:
Range: 75 – 426; default = *426
(Units = .01 inch)
18) LABEL ALIGNMENT
Sets the label alignment method
.
Section 4.6)
Possible Values:
YES
(user manually determines
'ALIGN LENGTH')
AUTO (printer determines 'ALIGN
LENGTH')
*
NO
(no Label Alignment
used)
(see