Comtech EF Data KST-2000B Installation And Operation Manual page 173

Ku-band satellite transceiver
Table of Contents

Advertisement

Ku-Band Satellite Transceiver
FSK Remote Control Commands
Parameter
Command
Type
(Instruction
Code and
qualifier)
Reference Stored
n.a.
Faults
HPA Stored
n.a.
Faults (2 and 4
Watt)
Arguments for
Description of arguments
Command or
(note that all arguments are ASCII numeric codes, that is,
Response to
ASCII codes between 48 and 57)
Query
6 bytes
Query only.
<add/RSF?X'cr'
>add/RSF=ABCDEF'cr''lf' or
>add/RSF=NO_FAULT'cr''lf'
Where: A=REF Source, 0=OK, 1=FLT
B=Oscillator State, 0=COLD, 1=EXT
C=72M Lock Status, 0=OK, 1=FLT
D=EXT REF Lock Status, 0=OK, 1=FLT
E=EXT REF Phase_N Status, 0=OK,
1=FLT, 2=NA
F=EXT REF Range Status, 0=OK,
1=FLT, 2=NA
X=Stored Fault Locations (0 to 9)
5 bytes
Query only.
<add/HSF?X'cr'
>add/HSF=ABCDE'cr''lf' or
>add/HSF=NO_FAULT'cr''lf'
Where: A=Overtemperature Status, 0=OK, 1=FLT
B=9.75V Status, 0=OK, 1=FLT
C=-5V Status, 0=OK, 1=FLT
D=BV1 Summary Status, 0=OK, 1=FLT
E=Interprocessor Comm.Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)
Response to Command (target to
controller)
RSF= (message ok)
RSF? (received ok, but invalid arguments
found)
RSF* (message ok, but not permitted in
current mode)
HSF= (message ok)
HSF? (received ok, but invalid arguments
found)
HSF* (message ok, but not permitted in
current mode)
E-21
Revision 9
MN/KST2000AB.IOM
Query
(Instruction
Code and
qualifier)
RSF?
HSF?

Advertisement