Ku-Band Satellite Transceiver
Operation
If the communication parameters for the system are not known, the Win-
dows™ based M&C system has a facility that will search all combinations of
address, baud rate, and parity until communication is established with the
system.
Using the KP-10 or terminal program, send a miscellaneous command such
as EQUIPMENT TYPE (see Appendix B.8) and confirm a response is dis-
played. The Windows™ based status screen will turn from RED to GRAY
when communication with the KST-2000A/B is established.
PC
OR
KP-10
TO DEMOD
FROM MOD
AC POWER
SOURCE
EXTERNAL
5/10 MHZ
REFERENCE
(OPTIONAL)
EARTH
GROUND
J2 REMOTE
J4 IF OUT
1:1 J10
J3 IF IN
RF OUT J6
HPA J8
J1 PRIME
RF IN J7
POWER
J9 REF IN
GND (ERDE)
KST-2000A/B
Figure 3-1. Single-Thread System
3–2
J1
HPA
J3
N/C
LNA/LNB
Revision 9
MN/KST2000AB.IOM
MONITOR
J2