Table 2-3. Remote M&C Connector (J2) Pin Assignments - Comtech EF Data KST-2000B Installation And Operation Manual

Ku-band satellite transceiver
Table of Contents

Advertisement

Ku-Band Satellite Transceiver
Installation
2.4.1.2
Optional –48VDC Prime Power Connector (J1)
Prime power is supplied to the converter unit (and for SSPAs of ≤ 8 Watts) through a
4-pin circular male connector (J1). For the converter unit, the prime power input
requirement is -36 to -48 VDC, 200 watts.
2.4.1.3
Remote Connector (J2)
The Remote Connector (J2) is a 26-pin, circular, female connector (P/N: PT06E16-
26P(SR) ). It is used to allow remote control and monitoring of KST-2000A/B operating
parameters. Interface is via EIA-232, EIA-485, or EIA-422 half-duplex. Refer to Table
2-3 for pin assignments.
Note: The user must assemble this cable. Figure 2-3 shows the connections for an
EIA-232 adapter for use with a PC COM port.
Table 2-3. Remote M&C Connector (J2) Pin Assignments
Pin
A
-TX/-RX or –RX only (see Note)
B
-TX/-RX or –TX only (see Note)
C
+TX/+RX or +RX only (see
Note)
D
+TX/+RX or +TX only (see Note)
E
RXD
F
RTS
G
TXD
H
DSR
J
GND
K
LNA Power
Optional –48VDC Power Connection
Pin
A
+ VDC
B
Ground
C
- VDC
D
No Connect
Mating connector is a Comtech P/N
CN/STPG04F01(Amphenol PT06E-12-4S(SR))
Signal
Function
Description
– EIA-485 TX/RX or – EIA-422 RX
–EIA-485 TX/RX or – EIA-422 TX
+ EIA-485 TX/RX or + EIA-422 RX
+ EIA-485 TX/RX or + EIA-422 TX
EIA-232 receive data
EIA-232 ready to send (tied to CTS)
EIA-232 transmit data
EIA-232 data set ready
Ground
+15 VDC to LNA
2–6
Revision 9
MN/KST2000AB.IOM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kst-2000a

Table of Contents