Operation
5.3.2

Monitor

The SELECT: MONITOR (Figure 5-6) menu is accessible from the SELECT menu.
When the MONITOR menu is entered, press [ ] or [ ] to select the desired function.
Each monitor function is displayed in real time for as long as it is selected.
The following listing describes each monitor function in detail.
Function
U/C TEMP
D/C TEMP
HPA TEMP
M&C TEMP
PWR FCTR
SUM FLTS

Figure 5-6. Monitor Menu

Description
Up converter temperature monitor.
Range: -40 to +90° C (-40 to 194° F)
Down converter temperature monitor.
Range: -40 to +90° C (-40 to 194° F)
HPA temperature monitor.
Range: -40 to +90° C (-40 to 194° F)
M&C temperature monitor.
Range: -40 to +90° C (-40 to 194° F)
The PWR FCTR is a power factor of the output power of
the CEFD HPA. In actuality, power factor is a very
close indication of the output power. This function is
only available with Comtech supplied SSPAs.
SUM FLTS are the summary faults of the complete
KST-2000A/B system. If there are any faults present,
they can be seen via a FLT indication in this menu.
5–9