On-Board Diagnostics
BMW
P-code
code
153
P0150
154
P0150
155
P0150
156
P0136
157
P0136
159
P0156
160
P0156
13 of 20
Fault type and
Signal type and
function
range
Oxygen sensor
Input analog
pre-cat (Bank 2),
(0-5V)
short to battery
volt.
Oxygen
Input analog
sensorpre-cat
(0-5V)
(Bank 2), short to
ground
Oxygen sensor
Input analog
pre-cat (Bank 2),
(0-5V)
disconnection
Oxygen sensor
Input analog
post-cat (Bank 1),
(0-5V)
short to battery
volt.
Oxygen sensor
Input analog
Post Cat. (Bank 1),
(0-5V)
short to ground
Oxygen sensor
Input analog
Post Cat. (Bank 2),
(0-5V)
short to battery
volt.
Oxygen sensor
Input analog
post-cat (Bank 2),
(0-5V)
short to ground
http://ebahn.bentleypublishers.com/BMW/3/E46/Repair%20Manuals/8...
Explanation
on input line.
Oxygen sensor signal range
is checked to determine if
electrical shorts exist on input
line. Voltage signal must be
within a predetermined range
(0.1V -1V) or fault will set.
Oxygen sensor signal range
is checked to determine if
electrical shorts exist on input
line. Voltage signal must be
within a predetermined range
(0.1V -1V) or fault will set.
Oxygen sensor signal range
is checked to determine if
electrical disconnection exist
on input line.
Oxygen sensor signal range
is checked to determine if
electrical shorts exist on input
line. Voltage signal must be
within a predetermined range
(0.1V -1V) or fault will set.
Oxygen sensor signal range
is checked to determine if
electrical shorts exist on input
line. Voltage signal must be
within a predetermined range
(0.1V -1V) or fault will set.
Oxygen sensor signal range
is checked to determine if
electrical shorts exist on input
line. Voltage signal must be
within a predetermined range
(0.1V -1V) or fault will set.
Oxygen sensor signal range
is checked to determine if
electrical shorts exist on input
line. Voltage signal must be
within a predetermined range
(0.1V -1V) or fault will set.