Heating and Air Conditioning
18 of 22
http://ebahn.bentleypublishers.com/BMW/3/E46/Repair%20Manuals/6...
programmed substitute value. See
Table
a.
Table a. Substitute programmed
values for IHKA component inputs
Input
Working
range
Heat
5° to
exchanger
124°C
sensor
(41° to
255°F)
Evaporator
-10° to
sensor
30°C (14°
to 86°F)
Interior
10° to
temperature
40°C (50°
sensor
to 104°F)
Exterior
K-bus
temperature
Coolant
K -bus
temperature
Specified
16° to
temperature
32°C (61°
to 90°F)
Note:
The substitute value for the evaporator
temperature sensor is below the A/C
compressor cycling temperature
(2°C/34°F). If the evaporator temperature
sensor signal is not plausible, the
substitute value will switch the A/C OFF.
Table b
lists resistance values and
fault limits for IHKA temperature sensors.
Table b. Temperature sensor
resistance values at 25°C (77°F)
Sensor
Resistance
Heater core
9 k
Substitute
value
55°C
(131°F)
0°C (32°F)
20°C (68°F)
0°C (32°F)
100°C
(212°F)
22°C (72°F)
Fault
limit
± 2%
Temp >