Appendix A: Reporting Codes - DSC Power 832 Installation Manual

Security system
Hide thumbs Also See for Power 832:
Table of Contents

Advertisement

Contact ID
The first digit (in parentheses) will automatically be sent by
the control panel. The last two digits are programmed to
indicate specific information about the signal.
For example, if zone 1 is an entry/exit point, the alarm
reporting code could be programmed as [34]. The central
station would receive the following:
*BURG - ENTRY/EXIT - 1
In the above example, the "1" indicates which zone went
into alarm.
Table A-1: PC5015 Reporting Codes
Section
Reporting Code
#
[320-323]
Zone Alarms
[324-327]
Zone Restorals
[328]
Duress Alarm
[328]
Opening After
Alarm
[328]
Recent Closing
[328]
Zone Expander
Supervisory
Alarm/Rest.
[328]
Cross Zone (Police
Code) Alarm
[329]
[F] Key Alarm/Rest.
[329]
[A] Key Alarm/Rest. Keypad auxiliary alarm (alarm and restoral
[329]
[P] Key Alarm/Rest. Keypad panic alarm (alarm and restoral reporting
[329]
PGM2 Alarm/Rest.
[330-]
Zone Tamper/Rest.
[337]
[338]
General System
Tamper/Rest.
[338]
Keypad Lockout
[339-343]
Closings
[343]
Partial Closing
[343]
Special Closing
Reporting Codes
A
P
P
E
N
Code Sent When...
zone goes into alarm
zone in alarm is restored
duress code entered at keypad
system disarmed with alarm in memory
alarm occurs within two minutes of system arming
panel loses/restores supervisory transmission over
the Keybus from zone expansion modules or
keypads with zone inputs
two zones on the same partition go into alarm
during any given armed-to-armed period (incl. 24-
hr zones)
Keypad fire alarm (alarm and restoral reporting
codes sent together)
reporting codes sent together)
codes sent together)
Output Option #23/24: a panic button wired to
PGM2 is pressed/access code is entered
Output Option #04: a 2-wire smoke detector wired
to PGM2 goes into alarm/alarm is cleared
zone exhibits a tamper condition/tamper condition
restored
enrolled module with tamper inputs has a tamper
alarm/all module tampers restored
max. number of incorrect access codes has been
entered at a keypad
system armed (user 01-34, 40-42 indicated)
one or more zones are manually bypassed when
system armed (or Auto-armed)
Closing (arming) using one of the following
methods: Quick Arm, Auto-arm, keyswitch,
wireless key, function key, maintenance code, DLS
42
D
I
X
V
A
SIA Format (Level 2—Hardcoded)
This format will send the account code along with its
data transmission. At the receiver, the transmission
would look similar to this example:
N Ri01 BA 01
N = New Event
Ri01 = Partition / Area Identifier
BA = Burglary Alarm
01 = Zone 1
Dialer
Direction*
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
O/C
O/C
O/C
Auto-
SIA Auto
matic
Rep Codes**
Contact
ID
(1) 3A
See
Table B-1
(1) 3A
(1) 21
HA-00
(4) A6
OR-00
(4) 59
CR-00
(1) 43
UA-00/UH-00
(1) 4A
BV-00
(1) 15
FA-00/FH-00
(1) AA
MA-00/MH-00
(1) 2A
PA-00/PH-00
(1) 4A
UA-99/UH-99
(1) 11
FA-99/FH-99
T/R
(1) 44
TA-ZZ/TR-ZZ
T/R
(1) 45
TA-00/TR-00
T/R
(4) 21
JA-00
(4) A2
CL-UU
(4) 7A
CG-00
(4) AA
CL-00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc5o15

Table of Contents