When the test tranmission cycle is programmed, the panel will send a test transmission the following day. This will
indicate the beginning of the new test transmission cycle to central station.
The panel can also send a test for the GSM1000 cellular communicator, if being used. If the GSM1000 Test
Transmission Code is programmed, the panel will send a cellular test at the interval programmed in the
GSM1000 Test Transmission Cycle.
The end user can generate a communicator test. If the System Test reporting code is programmed, the panel will send the
signal when the System Test keypad command is entered (see Section 3.4 – "[
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Test Transmission Reporting Codes .................... Section [352]
Test Transmission Time of Day .............................. Section [371]
Test Transmission Cycles ....................................... Section [370]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.14

Transmission Delay

If the transmission delay zone attribute is selected for a given zone, the panel will delay reporting an alarm for
that zone for the number of seconds programmed for the Transmission Delay Time. If the panel is disarmed
before the delay time expires, the panel will not report the event.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Transmission Delay Time ....................................... Section [370]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.15

Fire, Auxiliary, Panic Keys

The emergency keys are available on all keypads. These keys must be pressed and held for 2 seconds before they
will activate. This 2 second delay is designed to help prevent accidental activation.
If the Fire Keys option is enabled, when the Fire keys are pressed and held for 2 seconds, the panel will activate the
alarm output. It pulses one second on, one second off only if option 8 of Section [013] is disabled (Standard Fire option).
If Fire Bell Continuous is selected the alarm output will sound until a code is entered; otherwise it will sound until a code
is entered or the alarm output times out. Communication of the signal to the central station is immediate.
If the Auxiliary keys are pressed and held for 2 seconds the panel will sound the keypad beeper three times to verify
activation. The panel will beep the keypad ten times rapidly to verify communication to the central station.
If the Panic keys are pressed and held for 2 seconds, the panel will immediately communicate the signal to the central
station. If Panic Keys Audible is enabled, the panel will beep the keypad three times upon activation and activate the
alarm output until a code is entered or the alarm output times out. Otherwise the alarm will be completely silent.
The Fire, Auxiliary, Panic keys will operate even if Keypad Blanking and Keypad Lockout are active (See
Sections 5.23 "Keypad Lockout"and 5.24 "Keypad Blanking").
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Fire Keys Enable ..................................................... Section [015], Option [1]
Panic Keys Audible ................................................. Section [015], Option [2]
Fire Bell Continuous ............................................... Section [014], Option [8]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.16

Entry/Exit Delay Options

Upon arming, the panel will begin the Exit Delay. If Audible Exit Delay is enabled the keypad will beep every
second until the Exit Delay expires. The keypad will beep rapidly for the last 10 seconds of Exit Delay to warn the
user the system is about to arm.
For commercial applications Bell Squawk on Exit Delay may be enabled. The panel will squawk the alarm output once
every second when the Exit Delay is initiated and 3 times a second for the last 10 seconds until the Exit Delay expires.
Upon entry, if a Delay type zone is violated, the panel will begin Entry Delay. The keypad will emit a steady tone. The
keypad will pulse the keypad sounder during the last 10 seconds to warn the user the system is about to go into
alarm. If there was an alarm during the armed period, the keypad sounder will pulse for the entire Entry Delay to
warn the user of the previous alarm.
For commercial applications Bell Squawk on Entry Delay may be enabled. The panel will squawk the alarm output once every
second until the Entry Delay expires or the system is disarmed. This feature must not be used with 2 partitions.
Since two Delay zones are programmable, and therefore two different Entry Delays, when the panel is
armed it will use the Entry Delay for the first Delay zone violated.
If the Bell Squawk During Auto-arm option is enabled, the bell will squawk while the system is Auto-arming in order to
notify anyone on the premises that the system is being armed.
If Exit Delay Termination is enabled the panel will monitor the Delay zones during Exit Delay. If a Delay zone is violated
then secured during the Exit Delay, the Exit Delay will be terminated and the panel will be armed immediately.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Bell Squawk During Auto-arm ............................... Section [014], Option [2]
Bell Squawk on Exit Delay ..................................... Section [014], Option [3]
Bell Squawk on Entry Delay ................................... Section [014], Option [4]
Audible Exit Delay ................................................... Section [014], Option [6]
Exit Delay ................................................................ Section [005]
Entry Delay 1 & 2 .................................................... Section [005]
Exit Delay Termination ............................................ Section [014], Option [7]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
R
A
M
D
E
S
C
R
I
] Commands; [
34
P
T
I
O
N
] [6] User Functions").
S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc5o15

Table of Contents