P
R
O
G
If the panel is armed using the Stay function key, or by entering [!][9][access code], there will be no bell squawks
during entry and exit delays, except for the arm/disarm bell squawks.
If the panel is armed using the Stay function key there will be no bell squawks during the exit delay except
for the arm bell squawk. If the panel is no-entry armed using [ ✱ ][9][access code], there will be no bell
squawks during the exit delay, except for the arm/disarm bell squawks. There is no entry delay (and no bell
squawks) when the panel is no-entry armed.
If users will be disarming the system using a wireless key or a keyswitch, then both partitions must
have their own Delay 1 zones (zone type [01]).
To disarm the system using a wireless key, or a keyswitch, the entry delay must be active.
When the Alarms Displayed While Armed
Alarms Displayed While Armed
Alarms Displayed While Armed
Alarms Displayed While Armed option is enabled, zone alarm conditions will be displayed on all
Alarms Displayed While Armed
system keypads as they occur. This is a latching function and the alarms will be displayed until the system is
disarmed. This also occurs for 24-hour alarms when the system is disarmed.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Arm/Disarm Bell Squawk ....................................... Section [014], Option [1]
Bypass Status Displayed While Armed ................. Section [016], Option [7]
Opening After Alarm Keypad Ringback ................. Section [381], Option [1]
Opening After Alarm Bell Ringback ....................... Section [381], Option [2]
Closing Confirmation .............................................. Section [381], Option [4]
Alarm Displayed While Armed ............................... Section [018], Option [8]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.22

Automatic Arming

Each Partition can be programmed to Auto-arm at a specific time every day if it is in the disarmed condition. Up to 14
Auto-arm times can be programmed on the system: one for each day of the week for partition 1 and partition 2.
Once the Auto-arm times have been programmed, three items must be enabled in order to activate the Auto-arming
function:
1. The correct Time of Day must be programmed. For instructions on programming the time and date, see the PC5015
Instruction Manual ("Setting the Time and Date").
2. Enter [✱][6][2] to enable (three keypad beeps) or disable (one long beep) the Auto-arm feature.
3. Program the Auto-arm time for each day of the week, for each partition, in programming sections [180]-[193].
Items 2 and 3 are programmable by partition. Program these items at a keypad assigned to the correct
partition (See section 2.6 "Keypad Assignment").
If the Partition 1 Auto-arm Schedule in [✱] [6] feature is enabled, users with access to partition 1 will be able to
change the partition 1 Auto-arm time of day, for each day of the week. If the Partition 2 Auto-arm Schedule in [✱] [6]
feature is enabled, users with access to partition 2 will be able to change the partition 2 Auto-arm time of day for each day
of the week. See section 3.4 "[✱] Commands" for a description of the [✱][6][3] menu.
When the internal panel clock matches the programmed Auto-arm Time for that day, the panel will check the status
of the partition. If the partiton is armed, the panel will do nothing until the programmed Auto-arm time for the next day
when it will check again.
If the partition is disarmed, the panel will sound the buzzer of all keypads assigned to the partition for one minute.
This is the Auto-arm pre-alert period. Please note that if there is an auto-arm time programmed for that day, the
panel will sound the pre-alert whether or not Auto-arming is enabled (in the [✱][6][2] menu).
If a valid access code is entered during the Auto-arm pre-alert period, the Postpone Auto-arm Timer will begin. If
the timer programmed as [000], Auto-arming will be cancelled. If the timer is programmed from [001]-[225] minutes,
the panel will postpone Auto-arming for the programmed time. Once the timer is expired, the Auto-arming sequence
will begin again, at which point a valid access code may be entered to postpone the procedure. Auto-arming may
continue to be postponed multiple times. The panel will transmit an Auto-arm Postpone reporting code each time
auto-arming is postponed, if programmed.
If no code is entered, the panel will auto-arm. If a zone is violated the panel will transmit a Partial Closing reporting
code if programmed, to indicate the system was not secure. If the zone is restored the panel will add the zone back
into the system.
Automatic arming cannot be postponed using the Maintenance code.
If the Late to Close option is enabled, the panel will transmit the Late to Close reporting code whenever the Auto-
arm pre-alert sounds. If there is an Auto-arm time programmed for that day, the panel will transmit the reporting
code whether or not Auto-arming is enabled (in the [✱][6][2] menu). The Late to Close reporting code must also be
programmed for this feature to function.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Program Time and Date ......................................................................... [!][6][1]
Enable Auto-arming ................................................................................ [!][6][2]
Enable Auto-arm Day ............................................................................. [!][6][3]
Auto-arm Times ................................................................. Sections [180]-[193]
Auto-arm Postpone Reporting Code ............................................ Section [348]
Partial Closing Reporting Code .................................................... Section [343]
Late to Close Enable/Disable ..................................... Section [017], option [5]
Late to Close reporting code ........................................................ Section [343]
Partition 1 or 2 Auto-arm Schedule in [!][6] .... Section [017], options [2] & [3]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
R
A
M
D
E
S
C
R
I
36
P
T
I
O
N
S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc5o15

Table of Contents