A General System Trouble reporting code will be transmitted if the panel detects any of the following on the PC5204
Power Supply/Output Module: AC Power Failure, Low Battery, AUX Output Trouble, Output #1 Supervisory Trouble. The
General System Trouble Restoral reporting code will be transmitted when all of the listed problems are corrected.
A General System Supervisory Trouble reporting code will be transmitted if any module goes missing from the
Keybus. If the module is a zone expander the panel will also transmit the Zone Expander Supervisory Alarm
Trouble reporting code. The panel will send a General System Supervisory Restoral reporting code when the
problem is corrected as well as a Zone Expander Supervisory Restoral reporting code if the module is a zone
expander.
5.7.6

Zone Restorals

If the Restoral on Bell Time-out option is selected, the panel will send the Zone Restoral reporting code for the
zone if the bell cut-off time has expired and the zone is secured. If the zone is not secured when the bell cut-off time
expires, the panel will send the restoral immediately once the zone is secured, or when the system is disarmed. If
the Restoral on Bell Time-out option is not selected, the panel will immediately send the Zone Restoral reporting
code when the zone is secured, regardless of whether or not the alarm output is active.
24 Hour type zones will report the restoral immediately when the zone is secured.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Restoral on Bell Time-out ....................................... Section [380], Option [2]
AC Failure Communication Delay Time ................. Section [370]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
5.8

Downloading

Downloading allows programming of the entire control panel via a computer, modem and telephone line. All
functions and features, changes and status, such as trouble conditions and open zones can be viewed or
programmed by downloading. To verify operation, a Periodic DLS Callup occurs every 30 days at a random
time of day between 23:01-05:59.
The user must enter [ ✱ ][6][access code][5] to initiate a downloading session if Option 5 Section [401]
is enabled.
If the Answering Machine/Double Call option is enabled (or during the first 6 hours after power-up) the panel will
answer incoming calls for downloading provided the following conditions occur:
1. The panel hears one or two rings then misses a ring.
2. At this point the panel will start a timer.
3. If the panel hears another ring before the Answering Machine Double Call Timer expires it will answer on the
first ring of the second call.
The panel will immediately go on line and begin the download process unless the Call Back option is enabled. If
enabled, the panel and computer will both hang up. The panel will then call the Download Computer
Telephone Number and wait for the computer to answer. Once the computer answers downloading will begin.
If the Allow System Service option is ON, the user can activate the downloading feature for a set period of time
by entering [✱ ✱ ✱ ✱ ✱ ] [6] [access code] [5].
If the Full 6-hour User Enabled DLS Window option is enabled, when the user opens the DLS window with
[✱ ✱ ✱ ✱ ✱ ][6][access code][5], the DLS window will remain open for six hours. The DLS window will remain open after a
successful hang-up from a downloading call. If the One Time 1-hour User Enabled DLS Window option is
enabled, when the user opens the DLS window with [✱ ✱ ✱ ✱ ✱ ][6][access code][5], the DLS window will stay open for one
hour, and will close after a successful hang-up from a downloading call.
After six hours upon power-up, the panel will not answer incoming calls unless the Answering Machine/Double
Call option is enabled, or the Number of Rings is programmed to be more than [0].
If the User-Initiated Call-Up option is enabled, the user can have the panel initiate a call to the downloading
computer by pressing [✱ ✱ ✱ ✱ ✱ ][6][master code][6].
The Download Access Code and Panel Identifier Code are for security and proper identification. Both the panel and
the computer file should have the same information programmed before attempting to download.
The time to complete a successful download can be significantly reduced with the use of the PC-Link. This adaptor
makes it possible to perform on-site downloading. To Initiate Local Downloading via the PC-Link, enter [✱ ✱ ✱ ✱ ✱ ] [8]
[Installer Code] [499] [Installer Code] [499]. All keypads will be busy for the duration of the PC-Link connection. The
status LEDs will display the current system status on the keypad where the PC-Link was initiated. For more
information on connecting the PC-Link, refer to your "PC-Link Download Kit Instruction Sheet".
Downloading can also be performed through the GSM1000 cellular communicator if the phone line is
disconnected. If using the GSM1000 with Call-Back, you need to program the GSM1000 Preamble with the
downloading phone number in order for the panel to call the computer correctly.
When downloading labels for LCD keypads, only the LCD keypad assigned to slot 8 will receive the labels. In
addition, version 1.0 and version 2.0 LCD keypads are not compatible on the same system. For more