• Brightness Control
Brightness Control: When this option is selected the keypad will allow you to scroll through 10 different backlight level
Brightness Control
Brightness Control
Brightness Control
options. Use the arrow keys (<>) to scroll to the desired backlight level and press the [#] key to exit.
• Contrast Control
Contrast Control
Contrast Control: When this option is selected the keypad will allow you to scroll through 10 different contrast level options.
Contrast Control
Contrast Control
Use the arrow keys (<>) to scroll to the desired contrast level and press the [#] key to exit.
• Keypad Buzzer Control
Keypad Buzzer Control
Keypad Buzzer Control: When this option is selected the keypad will allow you to scroll through 21 different keypad
Keypad Buzzer Control
Keypad Buzzer Control
sounder tone options. Use the arrow keys (<>) to scroll to the desired keypad beeper level and press the [#] key to exit.
This function can be achieved on ICON/LED keypads by holding the [!] key.
[✱ ✱ ✱ ✱ ✱ ] [7]
Command Output Functions
There are four output functions available to the user. Entering [✱] [7] [1-4] [access code, if required] will activate any
output programmed for options [19]-[22] respectively. Each function can be performed when the system is either
armed or disarmed.
For more information regarding these output types, see Section 5.10 "PGM Output Options."
[✱ ✱ ✱ ✱ ✱ ] [8]
Installer Programming
Enter [✱][8] followed by the Installer Code to enter Installer Programming (See Section 4.0 "How to Program").
[✱ ✱ ✱ ✱ ✱ ] [9]
Arming Without Entry Delay
When a Partition is armed with the [✱][9] command the panel will remove the entry delay from the partition. After
the exit delay, Delay 1 and Delay 2 type zones will be instant and Stay/ Away zones will remain bypassed. (see
Section 5.1 "Zone Definitions" ) .
For more information regarding this feature, see the PC5015 Instruction Manual ("Alternate Arming Methods – Arming
Without Entry Delay").
The entry delay can be activated/deactivated at any time while the system is armed by pressing [✱][9].
[✱ ✱ ✱ ✱ ✱ ] [0] Quick Arm
If the Quick Arm Enable
Quick Arm Enable
Quick Arm Enable
Quick Arm Enable
Quick Arm Enable option is enabled the panel can be armed by entering [✱][0]. This is a useful method for
arming a partition when someone without an access code will be required to arm a partition.
The Quick Arm feature must be enabled in order for the Stay/Away function keys to operate as in-
tended. If the feature is not enabled, the user will be required to enter their access code after pressing
the Stay or Away function key in order to arm the system in the Stay or Away mode.
[✱ ✱ ✱ ✱ ✱ ] [0]
Quick Exit
Quick Exit will allow someone to leave an armed premise through a Delay type zone without having to disarm and
rearm the system.
When [✱][0] is entered, if the Quick Exit Enabled
exit. During this time the panel will ignore the first activation of a Delay type zone. When the Delay zone is secured
the panel will end the two minute time period.
If a second Delay zone is tripped, or if the zone is not restored after two minutes, the panel will start entry delay.
If Quick Exit is used on a partitioned system, Keypad Blanking and Access Code Required to Remove
Blanking should be enabled.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Quick Arm Enable ................................................ Section [015], Option [4]
Quick Exit Enable ................................................ Section [015], Option [3]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
3.5

Function Keys

There are five function keys on the PC5015 keypads labelled Stay, Away, Chime, Reset and Exit. The operation of these
keys is described below. The function is activated by pressing and holding the key for 2 seconds.
"Stay" - Stay Arm
Arms the partition to which the keypad is assigned. All Stay/Away type zones will be automatically bypassed.
Delay type zones will provide entry and exit delay. The keypad will not sound when a zone is violated during the
exit delay. After completing the exit delay, the keypad will sound 3 beeps, indicating that the system is armed.
The Quick Arm feature must be enabled for this key to function (Section [015], Option [4]) . If Quick Arming is not
enabled, the user must enter their access code after pressing the function key in order to arm the system in the
Stay mode.
"Away" - Away Arm
Arms the partition to which the keypad is assigned. All Stay/Away type zones will be active at the end of the exit
delay. Delay type zones will provide entry and exit delay. The Quick Arm feature must be enabled for this key to
function (Section [015], option [4]) . If Quick Arming is not enabled, the user must enter their access code after
pressing the function key in order to arm the system in the Away mode.
"Chime" - Door Chime On/Off
Pressing the key will toggle the Door Chime feature ON or OFF. One solid beep means the feature has been
disabled, three short beeps means it has been enabled.
"Reset" - Reset Shock Sensors/Smoke Detectors
Pressing this key will cause the panel to activate for 5 seconds any output programmed as Sensor Reset. (See
Section 3.4 "[ ✱ ] Commands, [ ✱ ][7][2]").
P
A
D
Quick Exit Enabled option is enabled, the panel will provide a two minute window to
Quick Exit Enabled
Quick Exit Enabled
Quick Exit Enabled
C