LE4000 Installation Manual

6.4 Inputs

The LE4000 has four inputs that can be used to trigger specific communications. These events transmit using the Contact ID or SIA
format with Inputs 1-4 reporting as [991] to [994] respectively.
Default settings are:
INPUT 1- BURGLARY ZONE
INPUT 2 - SUPERVISORY ALARM
These inputs are normally open and activate when a short condition is detected between the terminal and the COM. Refer to the wiring
diagram at the back of this manual.

6.5 Outputs

The LE4000 has two programmable outputs to activate in response to the associated events. Refer to the LE4000 Wiring Diagram at
the back of this manual for more information.

6.5.1 Activating the Outputs

The LE4000 has two open collector outputs capable of a maximum of 50mA. Internal events on the LE4000 can trigger the outputs to
turn on an LED or activate an input on the host panel. The default settings are as follows.
OUTPUT 1 Wireless Module or Network Trouble - Output is normally high and will switch to ground when the LE4000 can not
communicate with the LTE or 3G network.
OUTPUT 2 General Module Trouble - Output is normally low and will switch to high when a Wireless Network trouble, Power
Supply/Battery trouble, and/or a Failure to Communicate (FTC) trouble is detected.
Note: PGM2 must be connected to the control panel as shown in "LE4000 Wiring Diagrams" on page 22. Program the control panel
input Zone/Point as 24hr 'Supervisory' with keypad-only notification when activated. Output 2 on the LE4000 must be set as 'Active
High'.
Note: Once an output has been activated automatically, it will not restore its state until all the causes of activation are cleared.

6.6 Reporting Codes

LE4000 Reporting Codes
Zone 1 Activation
Zone 1 Restoral
Zone 2 Activation
Zone 2 Restoral
PSTN Line Down
PSTN Line Restoral
Input Loss
Input Restoral
Low Battery Alert
Low Battery Restoral
Periodic Test
Periodic Test with Trouble
Radio Activation
Internal Buffer Full
CID
SIA
Programmable
E130 991
FA 991
YES
R130 991
FH 991
YES
E300 992
PA 992
YES
R300 992
PH 992
YES
E351 000
LT 000
FIXED
R351 000
LR 000
FIXED
E337 000
YP 000
FIXED
R337 000
YQ 000
FIXED
E338 000
YT 000
FIXED
R338 000
YR 000
FIXED
E603 XXX
RP XXX
FIXED
E608 XXX
RY XXX
FIXED
R552 000
RS 000
FIXED
E624 000
JL 000
FIXED
14
Comments
Delayed 24 Hour Fire *
Delayed 24 Hour Fire Restore *
Panic Alarm *
Panic Alarm Restore*
Telco 1 Fault
Telco 1 Fault Restore
Power Supply Trouble
Power Supply Trouble Restore
Transmitter Battery Trouble
Transmitter Battery Restore
Test Transmission <Receiver Path>
Test Transmission <Receiver Path>
Remote Programming Successful