HEAT PUMP AND TANK ASSEMBLY
26. Mains Power Connection: Connect the mains power supply wiring to the
terminal block and earth connection inside of the lower front cover.
Secure the conduit to the side of the storage tank with a saddle.
"Connections – Electrical"
Refer to
and Installation Instructions supplied with the heat pump storage tank.
Note: The power supply to the water heater must not be switched on until
the installation is complete, the water heater is filled with water, air has
been purged from the heat pump circuit and a satisfactory megger reading
is obtained.
27. Lower Front Cover: Refit the lower front cover.
28. Water Connections: Connect the cold water supply and the hot water
pipe work to the storage tank.
Connect the temperature pressure relief valve and its drain line.
Refer to "Connections – Plumbing" in the Owner‟s Guide and Installation
Instructions supplied with the heat pump storage tank.
on page 30 and in the Owner‟s Guide
Step 26
connect wiring
28