24. Cable Set Connection: Route the cable set from the heat pump module
to the heat pump storage tank.
Unscrew the gland nut from the gland on the cable set and insert the
3 plugs, wires and nut of the cable set through the hole on the right
hand side of the electrical connection tab at the bottom of the lower
front opening.
It will be necessary to hold the gland nut at an angle to pass it through
the hole in the electrical connection tab.
Position the threaded end of the gland in the hole in the electrical
connection tab and tighten the nut onto the gland to secure in
position.
Connect the 3 plugs (4 pin, 3 pin and 2 pin) from the heat pump
storage tank into the 3 sockets from the cable set.
electrical connection tab
25. Cable Set Conduit: Fix the conduit of the cable set to the wall using
saddles, ensuring there is no loose play in the conduit between the heat
pump storage tank and the heat pump module.
Alternatively, the conduit may be positioned against either of the insulated
heat pump circuit flow and return pipes and secured with the cable ties
provided.
Coil up any excess conduit and neatly place behind the heat pump
module.
secure gland to
HEAT PUMP AND TANK ASSEMBLY
Step 24
27
connect plugs
to sockets