Configuring The User Lockout Threshold Number - Alcatel-Lucent OmniSwitch 6250 Management Manual

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

Configuring Global User Lockout Settings

Configuring the User Lockout Threshold Number

The lockout threshold number specifies the number of failed login attempts allowed during any given
lockout window period of time (see
ple, if the lockout window is set for 30 minutes and the threshold number is set for 3 failed login attempts,
then the user is locked out when 3 failed login attempts occur within a 30 minute time frame.
By default, the lockout threshold number is set to 0; this means that there is no limit to the number of
failed login attempts allowed, even if a lockout window time period exists. To configure a lockout thresh-
old number, use the
-> user lockout-threshold 3
A locked user account is automatically unlocked when the lockout duration time (see
User Lockout Duration Time" on page
account.
page 9-24
"Configuring the User Lockout Window" on page
user lockout-threshold
command. For example:
9-25) is reached or the admin user manually unlocks the user
OmniSwitch 6250/6450 Switch Management Guide
Managing Switch User Accounts
9-23). For exam-
"Configuring the
May 2012