Ni Module Behavior During Takeover - Alcatel-Lucent OmniSwitch 6250 Management Manual

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

Managing CMM Directory Content

NI Module Behavior During Takeover

If there are no unsaved configuration changes and the flash directories on both the primary and secondary
management modules have been synchronized through the
reloaded if a management module takeover occurs. As a result, data flow is not interrupted on the NIs
during the takeover.
If a configuration change is made to one or more NI modules (for example, a VLAN is configured on
several different interfaces) and the changes are not saved through the
corresponding NIs automatically reloads if a management module takeover occurs. Data flow on the
affected NIs will be interrupted until the reload is complete. Note that the NIs reloads whether the flash
synchronization status shows SYNCHRONIZED. This is because the unsaved changes have occurred in
the running configuration ( RAM), and have not been written to the configuration file of the flash direc-
tory. In this case, a list of only the affected NIs is displayed in the table output (for example, 1 6).
If the flash directories on the primary and secondary management modules are not synchronized (for
example, a
copy flash-synchro
if a management module takeover occurs. Data flow is interrupted on all NIs until the reload is complete.
OmniSwitch 6250/6450 Switch Management Guide
command has not been issued recently), all NIs is reloaded automatically
May 2012
Managing Redundancy in a Stack and CMM
copy flash-synchro
command, no NIs is
write memory
command, the
page 5-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 6450

Table of Contents