Alcatel-Lucent OmniSwitch 6250 Management Manual page 156

Hide thumbs Also See for OmniSwitch 6250:
Table of Contents

Advertisement

Managing Redundancy in a Stack and CMM
To synchronize the secondary CMM to the primary CMM, enter the following command at the prompt:
-> copy flash-synchro
The
copy flash-synchro
Guide.
Note. When synchronizing the primary and secondary CMMs, it is important to remember that the
boot.params file and the switch date and time are not automatically synchronized. See the OmniSwitch
6250/6450 Getting Started Guide for information on the boot.params file, and
System Files,"
for information on setting the switch date and time. The date and time are synchronized
using the
system time-and-date synchro
Synchronizing the System Date and Time
To synchronize the system date and time, use the
command synchronizes the secondary CMM date and time to the primary
Enter the command as shown:
-> system time-and-date synchro
page 5-28
command is described in detail in the OmniSwitch 6250/6450 CLI Reference
command.
system time-and-date synchro
OmniSwitch 6250/6450 Switch Management Guide
Managing CMM Directory Content
Chapter 1, "Managing
command. This
CMM
date and time.
May 2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 6450

Table of Contents