Xerox 7142 Service Manual page 263

Wide format printer
Table of Contents

Advertisement

RJ-901C/RJ-900C   Maintenance Manual
Table 9-6 Symptoms and Check Items for CPU System Serious Errors(Continued)
No.
Message
2
E 016 error
CPU Err
[00]
3
E 016 error
CPU Err
[02]
4
E 016 error
CPU Err
[03]
5
E 016 error
CPU Err
[04]
6
E 016 error
CPU Err
[05]
Event/
Check item
symptom
Interruption
1. Check AC power
exception
supply and plotter
error:
surrounding
Abnormal
equipment.
condition in
2. Check reappearance
interruption
by turning ON/OFF
process.
the machine power
Command
several times. Make
border
sure to perform this
exception/TLB
check repeatedly
exception (load
even if no problems
or command
seem to be present.
fetch) error:
(Make the same
Abnormal
condition as user's.)
condition in
command
border.
Or TLB
exception in
data load or
command
fetch.
Data border
1. Check serial
exception/TLB
number of the
exception
plotter.
(store) error:
2. Main board
Abnormal
assembly may be
condition in
defective.
data border.
Or TLB
exception in
data storing.
Address
exception error
(load or
command
fetch):
Address error
in command
load or fetch.
Address
exception error
(store):
Address error
in saving
process.
Contact our customer
support center.
Contact our
customer support
center.
Replace main board
assembly.
9-19
9 Troubleshooting
Action
Reference
Operation
Manual
"4.3.3
Replacing
Main Board
Assembly"
p.4-21

Hide quick links:

Advertisement

Table of Contents
loading