RJ-901C/RJ-900C   Maintenance Manual
CAUTION
When the plotter and PC are not directly connected with crossover cable but connected via
hub, the IP address needs to be different from that of devices on the network to be
connected. To connect via hub, consult with the network administrator.
(3) Starting Port Manager Mode
1. Connect the plotter network port and PC network port with a network cable.
NOTE
When connecting the plotter and PC on a one-to-one basis, use a "crossover cable". When connecting
the plotter and PC via hub, use a "straight cable".
2. When the plotter is in the operation status or in
the menu display status, press [Power] key to
turn the plotter off.
3. While holding down [Back] key in the operation
panel, press [Power] key.
The LCD displays [Board Manager Mode]. If
[Back] key is released, the display turns to
"Waiting for command".
NOTE
If "waiting for command" is not displayed, follow the steps below.
If IP address that is not default is displayed on the board, releasing [Back] key will display
[IP192.168.xxx.xxx] (depending on the set address) on the LCD. In this case, display either of the
default IP (IP 192.168.001.253) or the set IP address using [Forward feed] and [Backward feed],
and press [Enter]. Then, "waiting for command" will be displayed.
7-13