How To Replace Fuses; Battery On The Mother Board - Furuno FSV-35 Operator's Manual

Color scanning sonar
Hide thumbs Also See for FSV-35:
Table of Contents

Advertisement

8.3

How to Replace Fuses

The fuses in the processor unit, transceiver unit and hull unit protect them from over-
current and equipment fault. If the power cannot be applied, first check the fuse in the
processor unit and transceiver unit. If the power still cannot be turned on, have a qual-
ified technician check the fuses in other units.
Unit
Processor unit
Transceiver unit
Transceiver unit
(B voltage power
section)*
Transceiver unit
(DC power sec-
tion)*
Hull unit*
* For the replacement of the fuse, request service.
8.4

Battery on the Mother Board

The life of the battery on the Mother Board in the processor unit is approx. three years.
When the battery voltage is low the date and time data are not correct when there is
no GPS connection. When this occurs, have a qualified technician replace the battery.
Dispose of the battery in accordance with local regulations. Tape the + and - terminals
of the battery before disposal to prevent fire, caused by short circuit.
Type
FGB01 250V 20A
FGB01 250V 10A PBF
FGBO 250V 20A
FGBO 250V 10A PBF
FGBO 250 V 15A PBF
FGMB 250V 5A PBF
FGMB 250V 2A PBF
WARNING
WARNING
Use the proper fuse.
Use of a wrong fuse can cause fire or
damage the equipment.
8. MAINTENANCE, TROUBLESHOOTING
Code No.
000-155-775-10
For 12 VDC
000-155-787-10
For 24 VDC
000-155-786-10
For 100/110/115
VAC (2 pcs.)
000-155-839-10
For 220/230 VAC
(2 pcs.)
000-157-874-10
2 pcs.
000-157-570-10
2 pcs.
000-157-497-10
Remarks
8-3

Advertisement

Table of Contents
loading

Table of Contents