8. MAINTENANCE, TROUBLESHOOTING
8.2

Hull Unit Maintenance

Care for the hull unit by following the procedures shown below.
*
1
Equivalent greases:
SHOWA SHELL OIL: Shell Albania Grease S No.2
EXXON MOBIL: Mobilux EP No.2
NIPPON OIL CORPORATION: Multinox Grease No. 2
8-2
Apply MOLYTONE grease
#2 every six months.
Raise transducer and coat main
shaft with Daphne Eponex Grease
No.2 (IDEMITSU KOSAN CO.,LTD.*
every six months.
Dry dock ship and clean
transducer face yearly.
Apply single coat of
"MARINE STAR 20 Mod
(Red-N)" anti-foulant to
transducer face to keep
marine life off the transducer.
Do not paint metallic parts
such as the transducer
flange.
CAUTION
CAUTION
Replace anticorrosion zinc plate yearly.
Corrosion between the main shaft and
transducer may result, allowing water leakage
and/or loss of transducer.