6.3
Motor-driven tray
The movement of the motor-driven tray is mechanical by means of a stepper motor (1) in 24V
DC, controlled by two capacitive touch sensors (2) located at the front of the tray.
The two microswitches (3) are for the limit switch, and operation can be checked in test mode
(see Section 5.1)
1
3
2
2
3
3
3
PRIMEA 2007 Chapter 06
6/9
REV. 00 - Mar. 07