7.9
Boiler
To separate the boilers from the plastic
support, loosen the internal screw (G)
to release the coffee boiler. To remove
the temperature sensor, remove the red
indicated screw.
PRIMEA 2007 Chapter 07
REV. 00 - Mar. 07
Remove the safety guard by loosening
screw (F) and withdraw the boiler
assembly from the casing.
Loosen the external screw (H) to release the
steam boiler.
13/22