Fixing an intermittent error with a single drive on a SCSI bus
1. Replace the SCSI terminator on the tape drive.
2. Run the operation that caused the error. If the problem persists, the problem
3. Isolate which cable is causing the problem by replacing one cable at a time and
4. Replace the tape drive (see "Removing a SCSI tape drive from an enclosure" on
Fixing an intermittent error with multiple drives on a SCSI bus
Refer to the server's error logs to determine which tape drive is the source of the
problem:
v If only one tape drive is reporting a SCSI failure, replace that tape drive (see
v If multiple tape drives are reporting SCSI failures, the problem may be with the
54
IBM 200/400GB LTO-2 Tape Drive: User's Guide
– If the test runs successfully, replace the SCSI terminator first, then the
SCSI cable to that tape drive and interposer (if installed).
– If the test fails, replace the tape drive (see "Removing a SCSI tape drive
from an enclosure" on page 57).
v If the problem is with two or more tape drives, locate the first tape drive that
has the error and replace the SCSI cable that connects the tape drive and the
interposer (if installed).
may be with the cable.
running the operation that caused the error after each replacement. If the
problem persists after all cables have been replaced, the problem may be with
the Ultrium 2 Tape Drive.
page 57). If the problem persists, the problem is with your server. Consult your
server's documentation.
"Removing a SCSI tape drive from an enclosure" on page 57).
terminator or the SCSI cables:
– Replace the terminator and run the operation that caused the error. If the
problem persists, the problem may be with the cables.
– Isolate which cable is causing the problem by replacing one cable at a time
and run the operation that caused the error after each replacement.