1
5 UNLOCk OUTPUT*—
, 2 PULSES:
This programs the unlock output to one or two pulses. When the double
pulse unlock feature is turned on, the BLUE unlock wire supplies two
negative pulses instead of a single pulse. This makes it possible to di-
rectly interface with double pulse vehicles without any extra parts.
1
6 LOCk OUTPUT*—
, 2 PULSES:
This programs the lock output to one or two pulses. The GREEN lock
wire supplies two negative pulses instead of a single pulse. This makes
it possible to directly interface with double pulse vehicles without any
extra parts.
WITH UNLOCK
7 FACTORY ALARM DISARM*—
, BEFORE UNLOCk,
REMOTE START ONLY:
In the default setting the factory alarm disarm output will disarm the fac-
tory alarm system any time the button controlling Unlock is pressed. The
"Before Unlock" output disarms the factory alarm before the unlock output
activates and before remote start is activated. The "Remote Start Only"
output disarms the factory alarm only before the remote start is activated.
1
8 FACTORY ALARM DISARM PULSES—
, 2 PULSES:
Selectable for a single or double-pulse for the vehicle's factory alarm dis-
arm input requirements.
OFF (1)
9 COMFORT CLOSURE*—
:
The system can be programmed to close the windows when the system is
locked. If programmed ON, the lock output provides a 20 second pulse
when the system is locked. The output will be cancelled if the unlock but-
ton is pressed. In the Off setting the system will not do this function.
(2) Comfort closure 1 - Activates the 20 second timer after the door lock
pulse. (3) Comfort Closure 2 - Activates the 20 second timer with the door
lock pulse.