Roland EGX-600 User Manual page 148

Roland engraveing machine user's manual
Hide thumbs Also See for EGX-600:
Table of Contents

Advertisement

9-6. Specifications
Output Port Specifications (OUT1 to OUT8)
Number of output ports: 8 (sink-mode output)
Rated load voltage: DC 24 V
Maximum load current: 20 mA per port
Leakage current: 0.1 mA or less
Insulation method: Isolated photocoupler
Compatible connector: External-device input
Internal Circuit Schematic
Example of Connection to External Equipment
Expansion Connector 2
(No.)
(Signal)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
OUT 8
16
OUT 7
17
OUT 6
18
OUT 5
19
OUT 4
20
OUT 3
21
OUT 2
22
OUT 1
23
24
Chapter 9 - Appendix
144
+24V
External Equipment (PCL or the like)
PW
Common output
PW
IN 8
OUT 8
IN 7
OUT 7
IN 6
OUT 6
IN 5
OUT 5
IN 4
OUT 4
IN 3
OUT 3
IN 2
OUT 2
IN 1
OUT 1
NC
NC
PG
Common input
PG
IN 8
IN 7
IN 6
IN 5
IN 4
IN 3
IN 2
IN 1
PG
PG
0V
Output port
Do not apply loads greater than the forego-
ing to the output ports.
The output ports are assumed to be con-
nected to loads such as transistors. When
they are connected to an inductive load such
as a relay, be sure to connect a protect di-
ode to the coil to absorb counterelectro-
motive force. Improper connection may
damage the circuit.
Sink-mode
transistor output
Sink-mode input
Reversing the polarity of the power source may
damage the circuit. Be sure to check this before
you switch on the power. Also, do not attempt to
test the insulation.
Protect unused and never-connected (NC) pins so
that they do not accidentally short to other pins.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Egx-400

Table of Contents