9
Maintaining & Serv icing Your Appliance
A. G eneral Maintenance
1 . Creos ote ( Chimney) Cleaning
E very 2 months during heating season or as
recommended by a certified chimney sweep; more frequently
if chimney ex c e eds or is under 1 2 - 1 4 ft. ( measured from base
of appliance)
C ertified C himney Sweep
1. Remove all ash from the firebox and extinguish all hot embers
before disposal. Allow the appliance to cool completely. It is
also recommended that before each heating season the entire
system be professionally inspected, cleaned and repaired if
necessary.
2 . C lose the door tightly and proceed with sweeping the chimney.
3 . Sweep the collected ashes into the ash removal bo x , and empty.
Clean out the remaining ashes from firebox.
4 . O pen top- loading door and vacuum out.
In s pection : Inspect the system at the appliance connection and at
the chimney top. C ooler surfaces tend to build creosote deposits
q uick e r, so it is important to check the chimney from the top as well
as from the bottom.
F ormation and Need F or Remov al: W hen wood is burned slowly, it
produces tar and other organic vapors which combine with e x pelled
moisture to form creosote.
The creosote vapors condense in the relatively cool chimney flue
of a newly-started or a slow-burning fire. As a result, creosote
residue accumulates on the flue lining. When ignited, this creosote
creates an extremely hot fire which may damage the chimney or
even destroy the house.
T he chimney connector and chimney should be inspected once
every 2 months during the heating season to determine if a creosote
or soot buildup has occurred. If creosote or soot has accumulated,
it should be removed to reduce the risk of a chimney fire.
WARNING
F ire Ris k .
P revent creosote buildup.
• Inspect chimney connector and chimney once
every two months during heating season.
• Remove creosote to reduce risk of chimney fire.
• Ignited creosote is extremely HOT.
WARNING
F ire Ris k .
Do not use chimney cleaners or flame
colorants in your appliance.
W ill corrode pipe.
M arch 2 1 , 2 0 1 3
Is le Royale Wood Stov e
2 . As h Remov al Sys tem ( ARS) Operating and Cleaning
2 5 0 - 5 7 6 3 F
W eek l y when in constant operation or as
needed.
H omeowner
CAUTION
Inj ury Ris k .
• Gloves recommended
• Ash coals can remain extremely hot for
several days.
1 .
T he stove and ashes must be completely cooled down before
using the Ash Removal System.T he hinged door will open
from the right hand side. P ull ash pan out carefully.
2 .
C lean ash down through the ash removal system grate into
the drawer below. If there are large pieces in the ashes, you
can remove the grate before brushing the ash into the drawer.
3 .
B e sure to replace the grate before operating the stove.
Remember to leave 1 /4
firebox floor to act as a natural grate, allowing air to flow freely
underneath wood
4 .
Replace ash pan and close ash door handle. Dispose of the
ashes following the directions on page 2 3 .
Swings Open
F igure 2 7 . 1
WARNING
F ire ris k
Inj ury ris k
M ak e sure ash removal system door
Air leakage may cause:
• Over-fire condition.
• Flame and/or smoke spillage.
• Wood to burn too fast.
Do not operate with as h pan door open or
with as h pan remov ed.
DO NOT allow as hes to b uild up.
to 1 /2 inch ( 6 - 1 3 mm) of ash on the
Ash Door