D. Chimney Termination Req uirements
F ollow manufacturer' s instructions for clearance, securing
flashing and terminating the chimney.
M ust have an approved and listed cap
M ust not be located where it will become plugged by
snow or other material
Must terminate at least 3 feet (91cm) above the roof
and at least 2 feet ( 6 1 cm) above any portion of the
roof within 1 0 feet ( 3 0 5 cm) .
Must be located away from trees or other structures
E. 2 - 1 0 - 3 Rule
3 ft. (91cm)
Minimum
F igure 1 8 . 1
Wall or Parapet
F igure 1 8 . 2
P age 1 8
R
Is le Royale Wood Stov e
2 ft. (61cm)
10 ft. (305cm) To Nearest Roofline
10 ft. (305cm) or more
3 ft. (91cm) Minimum
NOTE:
Chimney performance may vary.
Trees, buildings, roof lines and wind conditions affect
performance.
Chimney height may need adjustment if smoking or
overdraft occurs.
Less than 10 ft. (305cm)
Pitched Roof
3 ft. (91cm) Minimum
Flat Roof
2 5 0 - 5 7 6 3 F
2 ft. (61cm)
3 ft. (91cm)
Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)Minimum